INTRODUCTION TO R410A - R407C
FAQ
Refrigerants Why use HFC?
|
- It is confirmed that neither R32 or R125, are toxic as R22.
- The cooling capacity of R134a is 40% lower than the R22. For this reason the R134a is not considered useful for cooling.
- The performance of HVAC R410A, is substantially higher than that of R407C.
- The refrigerant charging procedures are the same as R22.
- However we must be especially careful.
- Due to the high pressure that works. We have to use appropriate equipment and tools.
Protection of the Ozone Layer
What measures to protect the environment have been made about R22 devices already sold?
- It is necessary to take into account the protection of the ozone layer, pick the refrigerant for reuse or destruction, when repair or replacement of home air conditioning is performed.
- We try to use HFC equipment.
- With regard to the urgency of protecting the ozone layer, we must focus on collecting all the HCFC pair reuse or destruction.
- If we use more and more tasks HFC in our repair facility to get, though not immediately, have a high degree of use of HFC as the old equipment are completed life.
- In recent years, the installers instructions with respect to the vacuum process are given. This helps to reduce the discharge of refrigerant to the atmosphere. We must strengthen the use of vacuum process to minimize leakage of refrigerant.
- The trend toward alternative refrigerants walks. The R410A is used for small capacities, R410A and R407C capacities for medium and large capacities for R407C. However, the policy regarding refrigerants varies significantly from one manufacturer to another.
- The shift to alternative refrigerants, varies in accordance with the policies of each company.
Regulation of CFCs (chlorofluorocarbons)
CFC Why is regulated?
- Although the effect of CFCs on the environmental degradation vary, when they are released, they break down in the atmosphere. When they reach the stratosphere, ultraviolet rays strike them. The chemical reaction with the chlorine acts as a catalyst and reduces ozone.
- The hole caused by the reduction of the ozone layer, harmful ultraviolet radiation passes through it and reaching the Earth's surface.
- Using destroying ozone layer such as CFCs, must be regulated for environmental protection.
- According to the Montreal Protocol: With respect to the total amount so reduced in 1996 to 65% in 2004 to 35% in 2010 and will be completely banned in 2020.
The direct greenhouse effect (GWP)
What is the direct greenhouse effect of R410A?
- Theoretically, the performance of R410A is from 92% to 95% of R22, but, currently, the performance of R22 and R410A are equal.
- We're constantly improving our products in relation to energy saving. The GWP of R410 is 1740, similar to the R22 = 1700. We should minimize direct greenhouse effect, collecting all of the coolant and prevent leakage thereof into the atmosphere.
- No dates but considering that we have a long period of use of alternative refrigerants.
Installation and service with new refrigerant (R410A)
What can we say about the installation work?
- The installation method is basically the same. Given the high pressure of R410A, we have to use, pipes and tools adapted to these pressures.
- To avoid errors in the use of tools and provide security for the facility, we proceed to perform manual and hold seminars.
- As with R22, should prevent moisture.
- Due to the different type of oil used, the pipes should be perfectly clean before use with R410A.
- R410A requires pipes to withstand the pressures to which the cooling capacity trabaja.Cuando is 4kW or more.
- Keep in mind however, that for lower capacity 4Kw there pipes on the market which are not valid because they have inadequate wall thickness.
- The diameter of the R410A service ports is different from R22 to charging hoses can not be used. This prevents the load with the wrong coolant.
- R410A since no chlorine in their molecules, do not produce the same toxic substances as R22, but is also toxic.
- If refrigerant leak near a point where there is fire occur, ventilate the room as with R22.
- You can use HFC detector or soapy water. What does not work is the detector torch as having no chlorine, no reaction with flame.
- The R22 refrigerant will be collected and reused, so still available. When gradual reduction takes effect, it will be depleted in the absence of a balance between supply and demand.
- We are confident that the lack of supply will not be inconvenient to use R22 equipment.
- Due to the high pressure of R410A, this can not be used in R22 equipment for safety reasons.
- Due to the high pressure that works refrigerants would have to completely change the internal structure of the semi-industrial unit air conditioning, this makes it very difficult marketing R410A in semi-industrial equipment.
- Additional charges with R407C, are complicated, as this is a non-azeotropic refrigerant mixture. This reduces the ability to ensure good performance.